3-dimensional mapping system carto 3 Search Results


86
Biosense Webster 3 d mapping system
3 D Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/3d+mapping+system/pm40892973-39-17-21
Average 86 stars, based on 1 article reviews
3 d mapping system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster electroanatomic mapping system
Electroanatomic Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/electroanatomic+mapping+system/pmc13061657-122-13-18
Average 86 stars, based on 1 article reviews
electroanatomic mapping system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Johnson & Johnson medtech
Medtech, supplied by Johnson & Johnson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/johnson+johnson+medtech/10__1161_slash_circep__125__013911-51-15-13
Average 86 stars, based on 1 article reviews
medtech - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster 3 dimensional mapping system
3 Dimensional Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/anatomical+dimensional+mapping+system+three/pmc13136689-137-26-30
Average 86 stars, based on 1 article reviews
3 dimensional mapping system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster 3 dimensional navigation and mapping system • carto 3 system
3 Dimensional Navigation And Mapping System • Carto 3 System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/3+carto+system+%E2%80%A2/pmc12859562-4-0-9
Average 86 stars, based on 1 article reviews
3 dimensional navigation and mapping system • carto 3 system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster electroanatomical mapping system
Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular <t>electroanatomical</t> model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.
Electroanatomical Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/electroanatomical+mapping+system/pmc13005085-13-13-17
Average 86 stars, based on 1 article reviews
electroanatomical mapping system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Endocardial Solutions Inc 3-dimensional mapping system navx-ensite v.7.0
Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular <t>electroanatomical</t> model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.
3 Dimensional Mapping System Navx Ensite V.7.0, supplied by Endocardial Solutions Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/3+dimensional+mapping+system+navx+ensite+v+7+0/10__1161_slash_circep__114__001909-36-2-14
Average 90 stars, based on 1 article reviews
3-dimensional mapping system navx-ensite v.7.0 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Biosense Webster cardiac mapping
Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular <t>electroanatomical</t> model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.
Cardiac Mapping, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/cardiac+mapping+system/10__1016_slash_s2666___0849_ascii40_19_ascii41_30319___5-472-9-13
Average 86 stars, based on 1 article reviews
cardiac mapping - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster carto 3
Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular <t>electroanatomical</t> model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.
Carto 3, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/diamond+webster/pmc12861948-52-13-12
Average 86 stars, based on 1 article reviews
carto 3 - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster carto
Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular <t>electroanatomical</t> model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.
Carto, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/carto/10__1016_slash_j__hrcr__2025__11__006-34-10-15
Average 86 stars, based on 1 article reviews
carto - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster ventricular pacing
(A) 12‑lead electrocardiogram (ECG) during sinus rhythm. (B) Simultaneous ECG and intracardiac electrogram (EGM) recordings during <t>ventricular</t> extrastimuli demonstrate that the earliest atrial activation site is consistently at the distal electrode in the coronary sinus, regardless of coupling interval [400 ms (left) or 320 ms (right)]. These findings indicate the absence of decremental properties in the ventriculoatrial pathway. (C) 12‑lead ECG during narrow QRS complex tachycardia (SVT1) with a heart rate of 175 bpm. (D) ECG and EGM during SVT1 reveal that the atrial activation sequence during the tachycardia cycle (345 ms) is identical to that observed during ventricular pacing. Numbers indicate intervals in milliseconds.
Ventricular Pacing, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/pacing+ventricular/pmc12861948-23-6-16
Average 86 stars, based on 1 article reviews
ventricular pacing - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosense Webster octaray multipolar catheter
(A) 12‑lead electrocardiogram (ECG) during sinus rhythm. (B) Simultaneous ECG and intracardiac electrogram (EGM) recordings during <t>ventricular</t> extrastimuli demonstrate that the earliest atrial activation site is consistently at the distal electrode in the coronary sinus, regardless of coupling interval [400 ms (left) or 320 ms (right)]. These findings indicate the absence of decremental properties in the ventriculoatrial pathway. (C) 12‑lead ECG during narrow QRS complex tachycardia (SVT1) with a heart rate of 175 bpm. (D) ECG and EGM during SVT1 reveal that the atrial activation sequence during the tachycardia cycle (345 ms) is identical to that observed during ventricular pacing. Numbers indicate intervals in milliseconds.
Octaray Multipolar Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3-dimensional+mapping+system+carto+3/catheter+mapping+multipolar+%E2%80%A2/10__1016_slash_j__hrcr__2025__11__006-34-6-15
Average 86 stars, based on 1 article reviews
octaray multipolar catheter - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

Image Search Results


Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular electroanatomical model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.

Journal: HeartRhythm Case Reports

Article Title: Changes in QRS morphology during catheter ablation of premature ventricular complexes origination from right ventricular false tendon: A case report

doi: 10.1016/j.hrcr.2025.12.005

Figure Lengend Snippet: Intracardiac echocardiography view, 3D structure model, and QRS morphology changes of PVCs. A : ICE imaging shows the FT connected the APM and PPM. B : Right ventricular electroanatomical model in right anterior oblique and left anterior oblique projections showed the positions of the moderator band ( brown ), APM ( cyan ), FT ( purple ) and PPM ( rifle green ). The EAS was initially localized to the PPM apex ( pink tag ). Following ablation at this site, the EAS shifted to the FT-PPM junction ( blue tag ), with ultimate elimination of the PVCs achieved at the FT-APM junction ( yellow tag ). C1-C3 : QRS morphological alterations were documented during ablation at the corresponding EASs. A Purkinje-like potential was recorded during PVCs without identified during sinus rhythm ( red arrow ). APM = anterior papillary muscle; EAS = earliest activation site; FT = false tendon; MB = moderator band; PPM = posterior papillary muscle; PVCs = premature ventricular complexes.

Article Snippet: Considering the unusual QRS morphology of PVCs, using intracardiac echocardiography (ICE) with 3-dimensional electroanatomical mapping system (CARTO3; Biosense Webster, Inc) was required for identification of RV endocavitary structures.

Techniques: Imaging, Activation Assay

(A) 12‑lead electrocardiogram (ECG) during sinus rhythm. (B) Simultaneous ECG and intracardiac electrogram (EGM) recordings during ventricular extrastimuli demonstrate that the earliest atrial activation site is consistently at the distal electrode in the coronary sinus, regardless of coupling interval [400 ms (left) or 320 ms (right)]. These findings indicate the absence of decremental properties in the ventriculoatrial pathway. (C) 12‑lead ECG during narrow QRS complex tachycardia (SVT1) with a heart rate of 175 bpm. (D) ECG and EGM during SVT1 reveal that the atrial activation sequence during the tachycardia cycle (345 ms) is identical to that observed during ventricular pacing. Numbers indicate intervals in milliseconds.

Journal: Journal of Cardiology Cases

Article Title: Reentrant atrial tachycardia after catheter ablation of coronary sinus accessory pathway

doi: 10.1016/j.jccase.2025.05.004

Figure Lengend Snippet: (A) 12‑lead electrocardiogram (ECG) during sinus rhythm. (B) Simultaneous ECG and intracardiac electrogram (EGM) recordings during ventricular extrastimuli demonstrate that the earliest atrial activation site is consistently at the distal electrode in the coronary sinus, regardless of coupling interval [400 ms (left) or 320 ms (right)]. These findings indicate the absence of decremental properties in the ventriculoatrial pathway. (C) 12‑lead ECG during narrow QRS complex tachycardia (SVT1) with a heart rate of 175 bpm. (D) ECG and EGM during SVT1 reveal that the atrial activation sequence during the tachycardia cycle (345 ms) is identical to that observed during ventricular pacing. Numbers indicate intervals in milliseconds.

Article Snippet: Fig. 2 (A) Activation maps during ventricular pacing using the 3-dimensional anatomical mapping system (CARTO 3; Biosense Webster).

Techniques: Activation Assay, Sequencing

(A) Activation maps during ventricular pacing using the 3-dimensional anatomical mapping system (CARTO 3; Biosense Webster). The upper panel shows the initial activation map of the left atrium in the anterior-posterior (AP) view, with its earliest atrial activation site (EAAS) located at the anterior mitral annulus (MA). The lower panel demonstrates the activation map after the EAAS shifted to the lateral MA. Pink and red tags indicate the radiofrequency ablation sites along the anterior and lateral MA applied at 30 W for up to 60 s using the ThermoCool SmartTouch SF ablation catheter. (B) Tracings during ventricular extrastimuli without ( left ) and with ( right ) ventriculoatrial (VA) block. Coronary sinus (CS) recordings are displayed at twice the usual scale. Red arrowheads indicate low voltage and fractionated potentials immediately after ventricular far-field potentials at the CS electrodes, which are observed only in the presence of VA conduction. (C) Intracardiac electrogram at the distal electrode of the ablation catheter during ventricular pacing exhibits the accessory pathway potential fused with far-field ventricular potential. (D) Catheter positions at the successful ablation site in the left anterior oblique (LAO) projection. A few radiofrequency ablations were applied at 15 or 20 W, each for 30 s. ABL, intracardiac electrogram recorded from the ablation catheter.

Journal: Journal of Cardiology Cases

Article Title: Reentrant atrial tachycardia after catheter ablation of coronary sinus accessory pathway

doi: 10.1016/j.jccase.2025.05.004

Figure Lengend Snippet: (A) Activation maps during ventricular pacing using the 3-dimensional anatomical mapping system (CARTO 3; Biosense Webster). The upper panel shows the initial activation map of the left atrium in the anterior-posterior (AP) view, with its earliest atrial activation site (EAAS) located at the anterior mitral annulus (MA). The lower panel demonstrates the activation map after the EAAS shifted to the lateral MA. Pink and red tags indicate the radiofrequency ablation sites along the anterior and lateral MA applied at 30 W for up to 60 s using the ThermoCool SmartTouch SF ablation catheter. (B) Tracings during ventricular extrastimuli without ( left ) and with ( right ) ventriculoatrial (VA) block. Coronary sinus (CS) recordings are displayed at twice the usual scale. Red arrowheads indicate low voltage and fractionated potentials immediately after ventricular far-field potentials at the CS electrodes, which are observed only in the presence of VA conduction. (C) Intracardiac electrogram at the distal electrode of the ablation catheter during ventricular pacing exhibits the accessory pathway potential fused with far-field ventricular potential. (D) Catheter positions at the successful ablation site in the left anterior oblique (LAO) projection. A few radiofrequency ablations were applied at 15 or 20 W, each for 30 s. ABL, intracardiac electrogram recorded from the ablation catheter.

Article Snippet: Fig. 2 (A) Activation maps during ventricular pacing using the 3-dimensional anatomical mapping system (CARTO 3; Biosense Webster).

Techniques: Activation Assay, Blocking Assay